Gina Star

data aquisition and instrument control software

GINA Star is a data acquisition, evaluation, integration and control system for liquid and gas chromatography.
With simultaneous acquisition of up to 256 channels, GINA allows a monitoring and a full automation of a complete chromatography system.And now you are also able to control your HPLC System with Gina Star.
raytest supplies PC and GINA program for all radio-chromatography applications running under Windows 2000 / XP.
Download the latest demo version of Gina-Star.


Overview of Gina Star

Gina Star - Instrument control (F10)


GINA : General peak integration


GINA : General peak integration


Calibration

With Gina Star you are able to control following devices:


Pump control

Gina is able to control pumps of a ternary gradient solvent delivery system(quaternary upon request). It also allows control of all voltage and frequency controlled pumps.
The gradient profile can be designed by 27 steps of linear, concave or convex transition functions.
Gina is capable of controlling the following pumps :

Merck 6200 Kontron 420
Gilson 30x Jasco PU-980
HP 1050 Q Jasco PU-980 (LC)
Agilent (HP 1100 + 1200) HP 1090 SDS
Shimadzu SIL_6b Shimadzu LC-9a
Labomatic HD-200



Autosampler control

Gina allows passive control by autosampler via start/stop signal or full function control of autosampler by the program. Depending on the requirements Gina controls :
Gina is suitable for the following autosampler :

Shimadzu SIL-9a     HP 1090 SI
Shimadzu SIL-6b Jasco 851-AS (LS)
Gilson 231/2Labomatic ASIS-100
HP 1050 ALSAgilent ALS (HP 1100 + 1200)



Detector control

Multiparametric control of several detectors
RI - Detector : RAMONA 5
RAMONA 90
  RAMONA 92
  RAMONA 2000
  RAMONA Star
UV - Detector : UVIS 204
UVIS 206
Shimadzu SPD-6a SCL
Knauer UV-Mon
 Jasco UV-970/5
 Jasco UV-970/5 (LC)  
 Labocord 200/700
HP 1040 DAD
HP 1090 UV
HP 1050 VWD
HP 1050 MWD  
Agilent VWD (HP 1100 + 1200)
Agilent MWD (HP 1100 + 1200)
Agilent MWD with spectrum
analyze/acquisition (HP 1100 + 1200)
Fluorescence detector : Jasco 821-FP
Agilent (HP 1100 + 1200)
Jasco 821-FP (LC)


Column heater and switch : Agilent (HP 1100 + 1200)



Fraction collector control

The fraction collector control is based on a sophisticated peak detection procedure which reliably determines the appearance of small peak. In case fractions have to be collected for radioactive peaks separately and individually, delay to correct for time between cell and fraction collector is selectable.For exact manual fraction collecting a delayed cursor movement indicates the actual cutting time position.