LAS-3000 |
|
| |
Improved High End CCD-Imaging System |
|
| |
|
|
|
|
| |
- highest resolution: 3,2 million active pixels
- variable image size by means of hight-adjustable sample table
- image area from 105mm x 70mm to 250mm x 250mm
- highest sensitivity
- Peltier cooling down to – 30°
- pixel size 10,75 x 10,75 µm
- multiple pixel-binning setting possible
- high-sensitive Fujinon lens, F number 0.85
- 4 decades of data dynamics
- 16 bit Digitalization
- light integration on chip between 1/100 sec. to 30 h
- automatic focussing
- automatic adjustment of sample table
- 3 different measurement methods
- USB - 1.1 Interface
- all settings software controlled
- incident light unit included: Epi-blue (470 nm) and White (RGB); combo
unit
- options: automatic filter changer with 5 setting positions, UV-table,
white trans-illuminator with diffuser, emmision filter, microtiter tray,
Fresen lens
|
|
| |
Now see faint-light images with maximum sensitivity while
maintaning highest resolution |
|
| |
An improved design approach to both hardware and interface make imaging
of samples, even faint-light samples, a simple process. One-touch selection
of imaging modality and auto detection with auto focus simplify the exposure
process and increase the sample throughput of the LAS-1000plus system.
The result: easy to capture, high-resolution images of membrane, gel or
film samples up to 25x25 cm in size that are easy to analyze. The LAS-1000plus
permits the use of a variety of reagents including: CDP-Star®, ECL™,
ECLplus™ for chemiluminescence, EtBr, SYBR® Green I & II
,SYPRO® Ruby for fluorescence, and AttoPhos™ and ECLplus™
for chemifluorescence, so you can use the most appropriate method for
preparing and imaging your samples including documentation of autoradiographic
film.
|
| |
|
|
|
|
| |
Features previously unavailable with this level of image quality
and ease of use are: |
| |
|
|
| |
- intelligent Dark Box II, an auto-sensing enclosure that automatically
focuses the camera
- one-touch filter selection, with an option setting for use of custom
filters
- captured images are promptly displayed while using the automatic
range scope
- faint-light images are captured without a darkroom or special room
lighting
- documentation of gels, membranes, autoradiographic films, etc.
|
| |
 |
 |
| |
|
|
| |
Applications for LAS 3000:
|
|
| |
|
|
| |
| Fluorescence: |
Gel
Documentation, 1D
Gel Electrophoresis, 2D
Gel Electrophoresis, RFLP, Detection of PCR Products, High-Density
Array, Multilabelling,
In situ Hybridization, Histology,
Dot/Slot Blots,
Southern- Northern-
Western Blots, GFP
Expression Assay, TLC |
| Colorimetric Staining: |
Gel
Documentation, 1D
Gel Electrophoresis, 2D
Gel Electrophoresis, RFLP, High-Density Array, Histology,
Dot/Slot Blots,
Southern- Northern-
Western Blots, Colony Counting |
Chemiluminescence
Bioluminescence |
RFLP, Detection of PCR Products, High-Density Array, In
situ Hybridization, Histology,
Dot/Slot Blots,
Southern- Northern-
Western Blots, Luciferase Assay |
|
| |
|
|
| |
|
|